Technical Specifications
|
Model |
Power |
Size |
Rated Current |
Input Voltage |
Output Voltage |
Category |
Input Frequency |
Output Frequency |
Pressure Sensor |
|
VFA-16LS |
0.75KW |
226*170*127mm |
3.4A |
1x220V |
3x220V(△) |
Single-phase in and Three-phase Out |
50/60Hz |
20-50/60Hz |
4-20mA +24V 10bar |
|
1.1KW |
226*170*127mm |
5A |
|||||||
|
1.5KW |
226*170*127mm |
6.8A |
|||||||
|
2.2KW |
226*170*127mm |
9.6A |
|||||||
|
VFA-16LT |
1.1KW |
226*170*127mm |
3.2A |
3x380V |
3x380V(Y) |
Three-phase input, three-phase output |
|||
|
1.5KW |
226*170*127mm |
4.3A |
|||||||
|
2.2KW |
226*170*127mm |
5A |
Product Features:
- This inverter is used especially for water pump. It adopts the industry leading technique SPWM and pressure transmission technique, detects actual pipeline pressure change and controls the rotation speed of the pump.
- The operation of this device is very easy, all functions can be finished by parameters setting, without the need for professional debugging.
- This inverter is high-efficient, it can save water and electricity up to 20%~60% compared to traditional water supply system.
- Soft starting and stopping, constant water pressure, prolong the service life of the pipe network and make the water usage comfortable and enjoyable.
- Wide voltage range allows for stable operation even in areas with significant voltage fluctuations.
- The installation is very easy with direct screw thread, and different types of water pumps can be used, thus reducing the extra cost.
- LED display makes it convenient and fast to check and set actual pressure values.

Application
- Tap water booster system
- Household and residential water supply system
- Swimming pool water supply system
- Commercial water supply system
- Factory dormitory water supply system
- Industrial water circulation system
- Cooling water systems
- Cold water circulation system
Technical Parameters
|
No. |
Product Specification |
0.75KW |
1.1KW |
1.5KW |
2.2KW |
|
1 |
Input Power |
Single-phase AC Power supply or three-phase AC power supply |
|||
|
2 |
Input Voltage |
110VAC or 220VAC or 380VAC |
|||
|
3 |
Allowed Voltage Fluctuation |
80V~140V (110V) or 160V~260V (220V) or 320V~450V (380v) |
|||
|
4 |
Input Frequency |
50/60Hz |
|||
|
5 |
Output Voltage |
110VAC or 220VAC or 380VAC |
|||
|
6 |
Load Type |
Pump |
|||
|
7 |
Output Frequency Range |
20-50/60Hz |
|||
|
8 |
Pressure Sensor |
24V, 4-20mA (10 bar, 16 bar, 25 bar) |
|||
|
9 |
Pressure Setting Range |
0.5~9.0bar |
|||
|
10 |
Pressure Tank Setting Requirements |
Required not less than 2 liters inflatable pressure water tank (Preset pressure=60% of the setting pressure) |
|||
|
11 |
Temperature Range |
0~+40℃ |
|||
|
12 |
Medium |
Clean water within the temperature range of 0~+100℃ |
|||
|
13 |
Required Pressure When Self-starting |
When the factory setting pressure is less than 0.3 bar |
|||
|
14 |
Installation |
Make sure the grounding is appropriate and reliable before using. |
|||

Hot Tags: new lcd three-phase inverter, China, suppliers, factory, customized, cheap, pricelist, quotation, multi function pump inverter, pump inverter with remote control, pump inverter wholesaler, modular pump inverter, ac pump inverter, pump inverter