60HZ Frequency Conversion Water Pump

In order to keep the stopping pressure stable and stop normally, the VFD water pump must equip minimum 2L, maximum 24KL pressure tank, generally it is installed on the five-way, the shorter the distance is, the better the effect is; the larger the pressure tank capacity is, the better the effect is.
Send Inquiry

Product Introduction

Application

Residential, Industrial, Commercial Buildings, Family Homes and Villa, etc.


Products Description

image001


Technical Parameters

image003


Technical Data

ModelPowerInput voltageReted Flow (m3/h)Rated Head (m)Single-phase PUMP ModelOutput frequencyPressure sensor
VFWF-17M/2-200.37KW1x220V2.020CMF2-2020--60Hz4--20mA, +24V, (10bar, 16bar, 25bar)
VFWF-17M/2-310.55KW1x220V2.031CMF2-30
VFWF-17M/2-420.75KW1x220V2.042CMF2-40
VFWF-17M/2-510.75KW1x220V2.051CMF2-50
VFWF-17M/2-631KW1x220V2.063CMF2-60






VFWF-17M/4-240.75KW1x220V4.024CMF4-20
VFWF-17M/4-361KW1x220V4.036CMF4-30
VFWF-17M/4-421.1KW1x220V4.042CMF4-40






VFWF-17M/8-181KW1x220V8.018CMF8-10
VFWF-17M/8-281.5KW1x220V8.028CMF8-15






VFWF-17M/8-120.75KW1x220V8.012CMF8-10B
VFWF-17M/8-251.5KW1x220V8.025CMF8-20B






VFWF-17M/12-181.5KW1x220V12.018CMF12-10






VFWF-17M/12-151.1KW1x220V12.015CMF12-10B






VFWF-17M/16-141.5KW1x220V16.014CMF16-10


ModelPowerInput voltageReted Flow (m3/h)Rated Head (m)Three-phase PUMP ModelOutput frequencyPressure sensor
VFWF-17S/2-200.37KW1x220V2.020CMF2-20T (△)20--60Hz4--20mA, +24V, (10bar, 16bar, 25bar)
VFWF-17S/2-310.55KW1x220V2.031CMF2-30T (△)
VFWF-17S/2-420.75KW1x220V2.042CMF2-40T (△)
VFWF-17S/2-510.75KW1x220V2.051CMF2-50T (△)
VFWF-17S/2-631KW1x220V2.063CMF2-60T (△)






VFWF-17S/4-240.75KW1x220V4.024CMF4-20T (△)
VFWF-17S/4-361KW1x220V4.036CMF4-30T (△)
VFWF-17S/4-421.1KW1x220V4.042CMF4-40T (△)






VFWF-17S/8-181KW1x220V8.018CMF8-10T (△)
VFWF-17S/8-281.5KW1x220V8.028CMF8-15T (△)
VFWF-17S/8-361.85KW1x220V8.036CMF8-20T (△)
VFWF-17S/8-462.2KW1x220V8.046CMF8-25T (△)






VFWF-17S/8-120.75KW1x220V8.012CMF8-10BT (△)
VFWF-17S/8-251.5KW1x220V8.025CMF8-20BT (△)
VFWF-17S/8-392.2KW1x220V8.039CMF8-30BT (△)






VFWF-17S/12-181.5KW1x220V12.018CMF12-10T (△)
VFWF-17S/12-342.2KW1x220V12.034CMF12-15T (△)






VFWF-17S/12-151.1KW1x220V12.015CMF12-10BT (△)
VFWF-17S/12-312.2KW1x220V12.031CMF12-20BT (△)






VFWF-17S/16-141.5KW1x220V16.014CMF16-10T (△)






VFWF-17S/20-161.85KW1x220V20.016CMF20-10T (△)


ModelPowerInput voltageReted Flow (m3/h)Rated Head (m)Three-phase PUMP ModelOutput frequencyPressure sensor
VFWF-17T/2-200.37KW3x380V2.020CMF2-20T (Y)20--60Hz4--20mA, +24V, (10bar, 16bar, 25bar)
VFWF-17T/2-310.55KW3x380V2.031CMF2-30T (Y)
VFWF-17T/2-420.75KW3x380V2.042CMF2-40T (Y)
VFWF-17T/2-510.75KW3x380V2.051CMF2-50T (Y)
VFWF-17T/2-631KW3x380V2.063CMF2-60T (Y)






VFWF-17T/4-240.75KW3x380V4.024CMF4-20T (Y)
VFWF-17T/4-361KW3x380V4.036CMF4-30T (Y)
VFWF-17T/4-421.1KW3x380V4.042CMF4-40T (Y)






VFWF-17T/8-181KW3x380V8.018CMF8-10T (Y)
VFWF-17T/8-281.5KW3x380V8.028CMF8-15T (Y)
VFWF-17T/8-361.85KW3x380V8.036CMF8-20T (Y)
VFWF-17T/8-462.2KW3x380V8.046CMF8-25T (Y)
VFWF-17T/8-583KW3x380V8.058CMF8-30T (Y)






VFWF-17T/8-120.75KW3x380V8.012CMF8-10BT (Y)
VFWF-17T/8-251.5KW3x380V8.025CMF8-20BT (Y)
VFWF-17T/8-392.2KW3x380V8.039CMF8-30BT (Y)
VFWF-17T/8-523KW3x380V8.052CMF8-40BT (Y)
VFWF-17T/8-653KW3x380V8.065CMF8-50BT (Y)






VFWF-17T/12-181.5KW3x380V12.018CMF12-10T (Y)
VFWF-17T/12-342.2KW3x380V12.034CMF12-15T (Y)
VFWF-17T/12-363KW3x380V12.036CMF12-20T (Y)






VFWF-17T/12-151.1KW3x380V12.015CMF12-10BT (Y)
VFWF-17T/12-312.2KW3x380V12.031CMF12-20BT (Y)
VFWF-17T/12-483KW3x380V12.048CMF12-30BT (Y)






VFWF-17T/16-141.5KW3x380V16.014CMF16-10T (Y)
VFWF-17T/16-283KW3x380V16.028CMF16-20T (Y)
VFWF-17T/16-424KW3x380V16.042CMF16-30T (Y)






VFWF-17T/20-161.85KW3x380V20.016CMF20-10T (Y)
VFWF-17T/20-324KW3x380V20.032CMF20-20T (Y)


About Us

a) Why shall we install a pressure tank for the frequency drive water pump?

In order to keep the stopping pressure stable and stop normally, the VFD water pump must equip minimum 2L, maximum 24KL pressure tank, generally it is installed on the five-way, the shorter the distance is, the better the effect is; the larger the pressure tank capacity is, the better the effect is.

b) Do you produce single-phase variable frequency water pumps?

Yes, we produce single-phase variable frequency pumps. What technical parameters do you need for variable frequency pumps?

c) What is the protection level of your variable speed water pump?

IP54.

d) What is the nearest airport of your company?

First is Ningbo Airport, then Hangzhou or Shanghai Airport, welcome to visit us.

e) Do you have frequency inverter with WIFI function? How many meters can the receiving distance reach?

Yes, we produce frequency inverters especially for water pumps with WIFI function, the maximum receiving distance is 80 meters.

f) What is the difference of the connection for water pump between three-phase input & output and single-phase input and three-phase output inverter?

The connection method is different: Y-connection and △connection respectively.


Hot Tags: 60hz frequency conversion water pump, China, suppliers, factory, customized, cheap, pricelist, quotation, high performance water pump vfd, pump reverse osmosis pumps, pump inverter for sale, fault tolerant pump inverter, hvac pump inverter, soft start pump inverter