Maintaining Normal Operation of Permanent Magnet Motors: Preventing Demagnetization and Burnout

Once a permanent magnet motor loses its magnetism, replacement is usually the only option, and the cost of repair is also substantial. How to judge whether the permanent magnet motor has lost its magnetism? Let's find out below.

When the machine starts running, the current is normal. After a period of time, the current increases. After a long time, the inverter will be reported to be overloaded. First, you need to make sure that the inverter selected by the air compressor manufacturer is correct, and then confirm whether the parameters in the inverter have been changed. If there are no problems with both, you need to judge by back electromotive force, disconnect the machine head from the motor, perform no-load identification, and run it at no-load to the rated frequency. At this time, the output voltage is the back electromotive force. If it is lower than the back electromotive force on the motor nameplate by more than 50V, it can be determined that the motor is demagnetized.

 

info-791-555

 

How to keep permanent magnet motors working properly:

01 Keep the permanent magnet motor working at rated current

The main reason for the overload of the permanent magnet motor is that the excessive driven load, low voltage, or mechanical jamming in driven machinery, etc. If the overload time is too long, the permanent magnet motor will absorb a large amount of active power from the power grid, resulting in increased current and rising temperature. Under high temperature, the insulation of the permanent magnet motor ages, and the magnet steel may become demagnetized. Therefore, when the permanent magnet motor is running, it is necessary to regularly check whether the transmission system is operating flexibly and reliably; whether the concentricity of the coupling is standard; the flexibility of the gear transmission, etc. If there is a stuck phenomenon, it should be stopped immediately to find out the cause and eliminate the fault before running again.

 

02 Regularly check for balance in the three-phase current of the permanent magnet motor

For a three-phase AC permanent magnet motor, the current in any one phase must not differ by more than 10% from the average of the other two phases. Maintaining this balance is essential for the safe operation of the motor. If the imbalance exceeds this threshold, it indicates a fault in the motor that must be identified and addressed promptly.

 

03 Check the temperature of the permanent magnet motor

Regularly monitor the temperature of components of the permanent magnet motor, including the bearings, stator, and housing, for any abnormal changes.

Pay special attention to whether the motor bearings are overheating or lacking lubrication. If an excessive temperature rise is detected near the bearings, the motor should be shut down immediately for inspection. Check for cracks, scratches, or damage on the rolling elements and raceways of the bearings, excessive clearance or looseness, and whether the inner ring is rotating on the shaft.

If any of these issues are found, the bearings must be replaced before the motor is put back into operation.

 

04 Monitor for vibration and loud noise in the permanent magnet motor

If the permanent magnet motor exhibits vibration, it may lead to misalignment with the connected load, increasing the motor's load and causing it to operate under overload conditions, which can result in motor burnout.

Therefore, during the operation of the permanent magnet motor, especially the high-power permanent magnet motor, it is necessary to frequently check whether the anchor bolts, end covers, bearing glands, etc. are loose, and whether the grounding device is reliable. Any issues detected should be addressed promptly to ensure safe operation.

 

05 Keep the permanent magnet motor clean

During operation, the area within at least 3 meters around the air intake of the permanent magnet motor must be kept free of dust, moisture, and other debris. This is to prevent them from being drawn into the motor, which could create short-circuit medium or damage wire insulation, potentially leading to a short circuit and motor failure.

To ensure long-term safe and stable operation, the permanent magnet motor must maintain sufficient insulation resistance and operate in a well-ventilated, clean cooling environment.